Skip to main content
Skip table of contents

File location

The path that is entered must refer to a file. Either relative or absolute paths can be specified and these can be local or network paths.

FrmMain_HinweisgruppeEdit_Dateipfad.png

Output format

Specifies for which client the message file should be created for. The following options are available:

  • Default (a message file for the IBI-aws Client will be created)

  • Web (a message file for the IBI-aws WebClient will be created)

General

With IBI-aws WebClient

Only available if output format is Web

Specifies wheather the IBI-aws WebClient should also be written to the specified publication target.

Publication method

Specify which method should be used to write the remark file when publishing.

The following publish methods are available:

Delete and create (Default)

  1. Create a temporary remark file containing the current information

  2. Delete the existing remark file.

  3. Rename the temporary remark file

Replace

The remark file content will be replaced with the current information.

Rename and create

  1. Create a temporary remark file containing the current information.

  2. Rename the existing remark file (will be deleted at the next publish)

  3. Rename the temporary remark file.

Timeout

The timeout determines in which time span a failed publication is repeated.

If a publication fails, it is checked whether the timout has elapsed since the start of the publication. If the timout is not elapsed the publication will be repeated.

For example:

A publication fails after 3 seconds. Because the Timeout is set to 5 seconds and hasn`t yet expired, the publication is repeated.

5 seconds Timeout – 3 seconds publication = 2 seconds left

If the second publication fails after another 3 seconds, it is not repeated, because the Timeout has expired.

5 seconds Timeout – 3 seconds 1. Publication – 3 seconds 2. Publication = -1 seconds left

Expired messages

Publication offset

Specifies how long a message should be published after the end time has been reached.

Message tags

Only available if output format is Web

Write to message file

This option specifies whether the tags of the messages to be published should be written to the web output.

Privacy

Only available if output format is Default

Write data in plain text

If this option is selected, the message file will be written in plain text.

Obfuscate data

If this option is selected, the message file will be obfuscated.

Encrypt data

This option is only available if a certificate has been marked as "Active" for the message group in the tab Encryption.

If this option is selected, the message file will be encrypted with the certificate that was marked as "Active" for this message group.

Extended

Script execution

Scripts entered here are automatically executed using the Windows command line during the publishing procedure.

Examples

Powershell script
BASH
powershell "C:\scripts\myscript.ps1"
Batch script
BASH
C:\scripts\myscript.cmd

Error handling

If a script is not executed properly (ExitCode ≠ 0), the publication fails. The previously executed actions (script before publishing or writing the message file) are not reverted in case of an error.

Before publishing

Scripts entered here are executed before writing the message file.

After publishing

Scripts entered here are executed after writing the message file.

JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.